Return to product page

If your browser's Print dialog does not automatically appear, go to the File menu and select Print to print this product.

You can adjust the size of the printed text with the following buttons.


Atmosair 9000 Mattress

Atmosair 9000

Contact the suppliers for pricing and availability

(6 suppliers)

For information contact AT Aust on 1300 452 679

Short Description

An air filled, non electric mattress replacement system designed for pressure distribution. The mattress utilises atmospheric pressure and gravity to continuously adjust to the user's weight and movement via nine dynamic air cylinders and preset valves. Available in two sizes. Suitable for persons at low to medium risk of developing pressure injuries.

Additional Info

More Details

The mattress is designed to self adjust to displace body weight and reduce pressure. When body weight is placed on the mattress, a preset one-way output valve opens and allows air to escape. The valve shuts off when optimum internal pressure is reached. When body weight is shifted off a cylinder, one-way intake valves allow air to re-enter and refill the cylinder, which then returns to its original shape.

Structure
* The mattress is made up of two layers of high density foam separated by nine air cylinders positioned lengthwise which provide additional support under the torso and legs
* The top layer of foam is convoluted
* The mattress has a sloped heel section and is firm around the edges to facilitate transfers

Cover
* The mattress comes standard with a fluid resistant, multi-stretch cover

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

Place Of Manufacture

ArjoHuntleigh (United States of America)

Price Guide

Refer to supplier details for pricing.

Models And Options

Models

Only one model is available in two sizes.

Dimensions

Specification KA9REVG3575.S KA9REVG3580.S
Height 180 mm 180 mm
Length 1910 mm 2030 mm
Load Capacity (supplier stated) 227 kg 227 kg
Weight (kg) Unknown Unknown
Width 890 mm 890 mm

Setup And Maintenance

Maintenance

* Covers can be wiped to clean

Requirements

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Suppliers

Arjo Australia Pty Ltd (prev ArjoHuntleigh) (H/O WA)
78 Forsyth St
O'connor
WA 6163
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: Adrian Male (gen mgr)
Toll Free: 1800 072 040 (National Customer Care)
Email: AHACustomerService@arjo.com
Website: http://www.arjo.com/en-au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (NSW)
Level 2, 4 Talavera Rd
Macquarie Park
NSW 2113
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: David
Toll Free: 1800 072 040
Email: enquiries.au@arjo.com
Website: https://www.arjo.com/en-au/
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (QLD)
Unit 1
205 Queensport Road North
Murarrie
QLD 4172
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 07 3390 6544
Toll Free: 1800 072 040
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (SA)
489 South Rd
Regency Park
SA 5010
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 08 8363 1833
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (VIC)
10 / 1866 Princess Hwy
Clayton
VIC 3168
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
MaxAbility Consultants
Australia
Sales: 0422 419 984
Email: ram@maxabilityconsultants.com.au
Website: http://www.maxabilityconsultants.com.au/

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.