Product Detail

at magic logosubscribers   Login 
Send an email to make an enquiryEnquiry
PrintPrint
Alternating Overlay

Zenith Platinum Air PM265 Alternating Overlay System

An alternating air pressure overlay that fits over an existing mattress. It has seventeen air cells that alternate on a 9.6 minute cycle. Static pillow area and pin hole ventilation. Comes with a two way stretch anti microbial cover. A pump unit is supplied with the overlay and features static mode and sitting mode buttons. Manual weight adjustment to suit the user's weight. Single size overlay.

Learn More 
Features: Alternating Air, Low Air Loss, Washable, Water Resistant
  Alternating Overlay
Image Gallery: Alternating Overlay

Contact the suppliers for pricing and availability

(4 suppliers)

For information contact AT Aust on 1300 452 679

  • Additional info
  • Models and options
  • Dimensions
  • Setup and maintenance
  • Requirements

More Details

Platinum Air PM265 Overlay
* Seventeen cells of 130mm (5 inch) height
* Top three rows of cells are static
* Pin hole ventilation
* CPR facility at the head end of the overlay
* Elastic attachment to connect the overlay to the mattress
* Two year warranty
* Anti kink air hose connected to the pump unit

Cover
* Cover is two way stretch, water resistant and anti microbial
* Zipper cover
* Warm soapy water to clean
* 40kg minimum weight

Platinum Air PM265 Pump Unit
* The pump unit can only be used with the mattress recommended by the manufacturer
* The power switch is located at the side of the pump
* Power failure alarm. The panel will indicate whether this is caused by loss of pressure, power failure or mechanical fault
* Press the alarm mute button to suspend the low pressure alarm. Should the problem not be resolved within 5 minutes, the alarm will resume
* Inflate mode is the default mode when the power is turned on. When the maximum pressure level is reached, the pump will switch to Alternating
* Alternate mode. The normal operating mode of the system. Alternates every ten minutes
* Static mode. Stops the mattress alternating. Reverts back to alternating after 20 minutes
* Sitting mode. Additional seat pressure activated during backrest elevation to prevent bottoming out. May be activated in combination with the static mode or alone
* Lock feature. Should the panel remain untouched for 5 minutes, the panel lock will prevent accidental changing of the setting during normal operation. To unlock, press and hold the Panel lock for 3 seconds

Method Of Use

1. Connect the pump to the overlay.
2. Turn on the pump.
3. The mattress will take 20 minutes to fully inflate.
4. When the pump is started it begins the inflation mode and then changes to Alternate.
5. Once Alternate is illuminated the attendant sets the pressure to the appropriate weight of the user and makes adjustments for user comfort and clearance.
6. Once fully inflated and the user is laying on the mattress it is essential to test for clearance of at least 50mm between the user's sacrum and the base of the overlay.
7. Press the Therapy button to choose mode.

Considerations

* Static mode may be used while someone goes to sleep if they are finding it hard to fall asleep with the alternating mode
* The static mode allows attendants to perform therapy on a stable level surface
* Once fully inflated and the user is laying on the mattress it is essential to test for clearance of at least 50mm between the user's sacrum and the base of the overlay
* The supplier recommends that a mattress of at least 150mm is placed below the overlay to prevent bottoming out

Place Of Manufacture

Taiwan

More Details

Platinum Air PM265 Overlay
* Seventeen cells of 130mm (5 inch) height
* Top three rows of cells are static
* Pin hole ventilation
* CPR facility at the head end of the overlay
* Elastic attachment to connect the overlay to the mattress
* Two year warranty
* Anti kink air hose connected to the pump unit

Cover
* Cover is two way stretch, water resistant and anti microbial
* Zipper cover
* Warm soapy water to clean
* 40kg minimum weight

Platinum Air PM265 Pump Unit
* The pump unit can only be used with the mattress recommended by the manufacturer
* The power switch is located at the side of the pump
* Power failure alarm. The panel will indicate whether this is caused by loss of pressure, power failure or mechanical fault
* Press the alarm mute button to suspend the low pressure alarm. Should the problem not be resolved within 5 minutes, the alarm will resume
* Inflate mode is the default mode when the power is turned on. When the maximum pressure level is reached, the pump will switch to Alternating
* Alternate mode. The normal operating mode of the system. Alternates every ten minutes
* Static mode. Stops the mattress alternating. Reverts back to alternating after 20 minutes
* Sitting mode. Additional seat pressure activated during backrest elevation to prevent bottoming out. May be activated in combination with the static mode or alone
* Lock feature. Should the panel remain untouched for 5 minutes, the panel lock will prevent accidental changing of the setting during normal operation. To unlock, press and hold the Panel lock for 3 seconds

Method Of Use

1. Connect the pump to the overlay.
2. Turn on the pump.
3. The mattress will take 20 minutes to fully inflate.
4. When the pump is started it begins the inflation mode and then changes to Alternate.
5. Once Alternate is illuminated the attendant sets the pressure to the appropriate weight of the user and makes adjustments for user comfort and clearance.
6. Once fully inflated and the user is laying on the mattress it is essential to test for clearance of at least 50mm between the user's sacrum and the base of the overlay.
7. Press the Therapy button to choose mode.

Considerations

* Static mode may be used while someone goes to sleep if they are finding it hard to fall asleep with the alternating mode
* The static mode allows attendants to perform therapy on a stable level surface
* Once fully inflated and the user is laying on the mattress it is essential to test for clearance of at least 50mm between the user's sacrum and the base of the overlay
* The supplier recommends that a mattress of at least 150mm is placed below the overlay to prevent bottoming out

Place Of Manufacture

Taiwan

Models

* PM265 Mattress Overlay
* PM268 Replacement Mattress

Specification PM265 Overlay PM295 Overlay
Height   130 mm
Length 200 mm  
Load Capacity (supplier stated)   From 40 kg to 160 kg
Weight (kg) 2.2 kg  
Width 900 mm  

Maintenance

Refer to the supplier and manufacturer manual for maintenance instructions and safety warnings.

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.

Suppliers

Supplier Location Contact Website
GMS Rehabilitation (VIC - Geelong) Geelong, VIC, Australia Sales: 1300 734 223
Fax: 1300 734 553
  Visit Website 
GMS Rehabilitation (VIC - Kialla) Kialla, VIC, Australia Sales: 1300 734 223
Fax: 1300 734 553
  Visit Website 
GMS Rehabilitation (VIC - Lynbrook) Lynbrook, VIC, Australia Sales: 1300 734 223
Fax: 1300 734 553
  Visit Website 
GMS Rehabilitation (VIC - Traralgon) Traralgon, VIC, Australia Sales: 1300 734 223
Toll Free: 1300 734 553
  Visit Website 

Similar Products

  • 21142015
    Oska Alto Series 3 - V4
  • 21142013
    Carilex MedexCare Alternating Air Mattress
  • 2117007
    CuroCell 4 Mattress Replacement System
Loading...
Ref 21:14:004
ISO 04.33.06
  • Contact
  • Donate
  • Virtual Tour
  • Disclaimer
  • Terms
  • Privacy
  • Home
  • Login/Sign-Up
  • Site Help
  • Feedback
  • Copyright & Disclaimer
  • Terms of Use
  • Privacy Policy
  • Who We Are
  • News & Events
  • Our History
  • Meet Our Team
  • Become a Member
  • Donate
  • Useful Links
  • What We Do
  • Client Services
  • Access
  • Training
  • @magic
  • AT Collaboration
  • Research
  • Assistive Technology
  • Browse Products
  • Product Search
  • 2nd-Hand Register
  • Suppliers Directory
  • @magic
  • Access
  • Access Consultancy
  • Access Training
  • Access Projects
  • Training
  • Publications
  • Strategic Plan
  • Annual Reports
  • Journal Extracts
  • @ a Glance Guides
  • Contact Us

Address

Assistive Technology Australia
(Independent Living Centre NSW)
Shop 4019 Westpoint Blacktown
17 Patrick Street
Blacktown
NSW 2148
Australia

Find Us

Shop 4019
Level 4 (Rooftop)
Westpoint Shopping Centre Blacktown
Enter car park via express ramp at the Alpha St roundabout (Map)

1300 452 679
02 9912 5800 (Reception)

02 8814 9656 (Fax)

Email: welcome@at-aust.org
Feedback:feedback@at-aust.org

Facebook: ILCNSW

ABN 44103 681 572

 

Copyright © 2009-2020 Independent Living Centre NSW trading as Assistive Technology Australia. Logo and name are trademarks of the Independent Living Centre NSW.