Short Description

A fully automatic therapeutic high end alternating one in two cell cycle (12 minutes) powered pressure relief air mattress replacement system used for prevention and treatment of superficial pressure injuries or anyone with a past history of pressure injuries. Recommended for anyone at low to medium risk of developing pressure injuries. Removable Dartex coated clinical top cover which is waterproof, two way stretch, vapour permeable and is also machine washable.

Additional Info

More Details

* Suitable for hospital, nursing home, rehabilitation and private home community use
* Replaceable air cells top deck
* Heavy duty replaceable non - kink air tubing and power unit parts e.g. Piston compressor (longer life span)
* Silent power control unit
* Transport feature keeps the mattress inflated during transportation or blackouts

Structure
* Quick release Cardio pulmonary resuscitation (CPR) Emergency valve
* Patent pending welded air cells for optimum user comfort (No bottoming out)
* Polyurethane sealed seams and waterfall flap for total infection control
* Heavy duty fire retardant power unit casing
* Push mode childproof power unit control panel
* Mattress and power unit meets all International, Australian and TGA standards

Attachment
* Mattress: secures firmly to any profiling/ non - profiling bed frame platform with adjustable nylon straps on all corner points
* Power unit: secures with two hangers safely over the bed footboard

Power Control Unit
* Electric 220/240V
* Attaches to mattress with umbilical cords
* Is portable when using together with the Daycare dynamic alternating seating cushion
* On / Off switch
* Fully automatic (Interface pressure gets adjusted to the user weight)
* Illuminated colour coded display status, audible and visual alarm, user guide supplied
* User friendly operating mode

Cover
* Removable for laundering and fitted to under mattress
* Dartex material: Washable, anti-static, anti-allergenic, biocompatibility, breathable, fire retardant, two way stretch, waterproof, weldable seams (optional) and easy to slide patient up and down the mattress on the smooth top cover surface finish reducing shear and friction

Customised Features
* Can be customised to fit any non single beds e.g. King, King-single, Queen, etc.
* Partners can still sleep comfortably beside one another
* Available in Standard and Extra Narrow widths

Safety Features
* Warning Signals: Service, low pressure, power failure, CPR deflate, inflate mode
* Easily accessible quick release CPR handle (overlay deflates under 10 seconds)
* Side formers help with patient transfers or when sitting in or out of the bed

Cleaning (Mattress, Power Control Unit and Power Lead)
* Using a sponge with hot water at 60 degrees C and with a 10:1 mixture of sodium hypochlorite/detergent (Bleach) clean the product in order; removing excess cleaning liquid after each step
* Umbilical cord moving towards the mattress
* The underside of the mattress
* Sides and under flaps
* Mattress top surface
* Front, rear, top, bottom and side panels of motor including power lead
* Dry thoroughly using single use clean paper towels
* (Please refer to product user manual for machine washing instructions)

Considerations

All pressure reduction products must be monitored to prevent any 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony prominences are pressed against the surface below the mattress or seating cushion. Where bottoming out occurs even with correct use (e.g. correct inflation levels), a different product may need to be used. User weights can change over time and the weight limit including linen on bed etc should not exceed the recommended product safe working load limit.

If non - blanchable erytheme is observed either reposition the patient more frequently or upgrade to a higher level support surface.

The mattress and cushion can be punctured.

Place Of Manufacture

United Kingdom and Australia

Price Guide

Contact supplier for pricing
Price on application from Watercomfort

Models And Options

Models

One model available for Australia

Dimensions

Specification Mattress Overlay
Height 205 mm
Length 1900 mm
Load Capacity (supplier stated) From 30 kg to 200 kg
Weight (kg) Unknown
Width 880 mm

Additional Dimensions

Compressor
Weight (kg) NSW................................... 3.1 kg
Length NSW........................................ 130 mm
Height NSW........................................ 300 mm
Width NSW......................................... 220 mm

Setup And Maintenance

Maintenance

12 monthly service is recommended to get the full life span of the product (Approx.10 years). This can be arranged thru Pegasus Healthcare. Avoid dropping the power unit or accidental piercing e.g. needles, exposed springs from bed fame or cigarette burns. Motor and mattress can be repaired as necessary.

Requirements

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Suppliers

Pegasus Healthcare (ACT)
64 Dundas Court
Phillip
ACT 2606
Australia
Sales: 02 6282 0533
Website: http://www.pegasushealthcare.com
Pegasus Healthcare (NSW)
Unit 1 30 Heathcote Rd
Moorebank
NSW 2170
Australia
Sales: 1300 303 603
Fax: 02 9601 7870
Contact Person: Lesley Carter
Email: moorebank@hospitalathome.com.au
Website: http://www.pegasushealthcare.com
Pegasus Healthcare (QLD)
24 Expo Court
Ashmore
QLD 4214
Australia
Sales: 07 5503 5444
Website: http://www.pegasushealthcare.com
Pegasus Healthcare (VIC)
437 Nepean Hwy
Brighton
VIC 3186
Australia
Sales: 03 9596 6377
Website: http://www.pegasushealthcare.com
Pegasus Healthcare (WA)
19 Dillenia Way
Greenwood
WA 6024
Australia
Sales: 08 9343 6101
Website: http://www.pegasushealthcare.com
Watercomfort Co, The
42 Alexander Ave
Taren Point
NSW 2229
Australia
Sales: 02 9531 1699
Fax: 02 9531 1799
Contact Person: Ann Marie Knox
Toll Free: 1300 734 664
Email: sales@watercomfort.com.au
Website: http://www.watercomfort.com.au

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.