TheraKair Visio Air Pulsation Mattress Replacement

Visio Replaceable Cells

Contact the suppliers for pricing and availability

(5 suppliers)

For information contact AT Aust on 1300 452 679

Short Description

TheraKair Visio is a mattress replacement system designed to manage all extrinsic causes of pressure injury development for people at high risk of pressure injuries. It uses silent low air loss, Gore-Tex medical fabric and pulsation therapy to deliver pressure, shear and friction relief, manage the skin's microclimate and improve blood and lymph flow. The system is operated from an intuitive touch screen.

Additional Info

More Details

Functions
* Low Air Loss:
* Conforms to bony prominences, minimising deformation of body tissue
* Allows patient to sink into mattress evenly distributing pressure
* Helps reduce pressure induced pain
* Pulsation Therapy:
* Can be effective in managing oedema and pain, using small pockets of air, individually inflated and deflated, to cause a pulsation wave
* The pulsation wave runs from the foot to the head of the mattress
* Reduction in oedema increases blood flow and reduces pain
* Improves capilliary blood flow, increasing oxygenation to the wound and skin
* Pulsation Therapy mimics the body's natural intermittent movements stimulating lymphatic flow. Lymphatics have little contraction ability in their own right and rely on movement to stimulate lymph flow
* Patient Warmer:
* Warmed air can pass through Gore-tex Medical Fabric and circulate around patient, increasing patient comfort
* Instaflate:
* Inflates mattress to its maximum firmness for ease of patient placement and care

Structure
* Individual cells are replaceable

Pump / Controls
* Quiet operation
* Intuitive Touch Screen
* An easy to navigate 'touch screen' interface gives details of system status and allows for easy and precise therapy adjustment

Cover
* GORE-TEX Medical Fabric:
* Smooth laminate surface reduces frictional drag and shear
* Designed for managing the skin's microclimate. This is due to high MVTR (Moisture Vapour Transmission Rate) to prevent skin maceration
* Waterproof to reduce contamination of mattress
* Bacterial barrier to help prevent infection
* Air flows through Gore-Tex at a controlled rate, removing excess moisture and maintaining a constant skin temperature, whilst preventing bacterial contamination. It provides a consistent bacterial barrier to 0.2 mic particle size

Indications
* TheraKair Visio is currently indicated for:
* Prevention and treatment of pressure injurys
* Patients requiring pain management
* Oedema management

Safety Features
* CPR - One quick movement evacuates air from the mattress in a maximum of ten seconds
* During operation, an alarm will sound and an alarm message will be displayed if a fault is detected

Contraindications
* TheraKair Visio is currently contraindicated for patients with:
* Cervical traction
* Unstable spinal cord injury

TheraKair Visio?
* Side Rails and Restraints: use or non-use of restraints, including side rails, can be critical to patient safety. Warning: serious injury or death can result from the use (potential entrapment) or non-use (potential patient falls) of side rails or other restraints
* Patient Migration: as with all specialty bed products that are designed to reduce shear and pressure on the patient's skin, the risk of gradual movement and/or sinking into hazardous positions of entrapment and/or inadvertent bed exit may be increased
* Skeletal Traction: with skeletal traction, use care to guard against risks of patient migration or inadvertent deflation of air surface

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

Place Of Manufacture

ArjoHuntleigh

Price Guide

Complete System Code M8259978/AU = $14,400
Mattress only Code M6265526 = $5900
Pump only Code M6257763 = $8500

Models And Options

Models

One model is available

Dimensions

Specification Mattress
Height 200 mm
Length 2080 mm
Load Capacity (supplier stated) Unknown
Weight (kg) 13.2 kg
Width 900 mm

Additional Dimensions

Compressor
Weight (kg) NSW................................... 6.3 kg
Length NSW........................................ 260 mm
Height NSW........................................ 210 mm
Width NSW......................................... 410 mm

Requirements

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Additional Images

Visio Touch Screen Visio Mattress & Pump

Suppliers

Arjo Australia Pty Ltd (prev ArjoHuntleigh) (H/O WA)
78 Forsyth St
O'connor
WA 6163
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: Adrian Male (gen mgr)
Toll Free: 1800 072 040 (National Customer Care)
Email: AHACustomerService@arjo.com
Website: http://www.arjo.com/en-au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (NSW)
Level 2, 4 Talavera Rd
Macquarie Park
NSW 2113
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: David
Toll Free: 1800 072 040
Email: enquiries.au@arjo.com
Website: https://www.arjo.com/en-au/
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (QLD)
Unit 1
205 Queensport Road North
Murarrie
QLD 4172
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 07 3390 6544
Toll Free: 1800 072 040
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (SA)
489 South Rd
Regency Park
SA 5010
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 08 8363 1833
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (VIC)
10 / 1866 Princess Hwy
Clayton
VIC 3168
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.