Citadel Plus Bariatric Care System

Citadel Plus Bariatric Care System
Call supplier for a price

Confirm with the suppliers for pricing and availability

(5 suppliers)

For information contact AT Aust on 1300 452 679

Last updated: Nov 17 2021

Short Description

An electrically operated bed with adjustable backrest, bed height adjustment, integrated weigh scale and an optional tilting (Trendelenburg and Reverse Trendelenburg).The Citadel plus has four easy to use split side rail controls included with the bed controls.

Additional Info

More Details

Frame
* Check with supplier for further details

Headboard / Footboard
* Check with supplier

Adjustments
* Incorporates 3 width expansion options.
* Also can be changed into a chair position by lowering the legs
* Adjustable Backrest angle
* Bed height and leg elevation adjustment
* Electrical calf adjustment system (knee break)

Controls
* Power Drive Controls
* Weighing/Movement Detection system Controls

Mattress
* AtmosAirTM plus non powered pressure redistribution surface along with Skin IQ 1000

Castors
150mm dual castors

Bed Rail
* Folding split side rails with integrated bed controls

Safety Features
Provides visual alerts on 4 bed conditions
* Side rail position
* Brake status
* Bed height
* if VariZone is alarmed which is a patient detection and exit detection system

Additional features
* Under bed lights
* Drainage bag rails
* under bed light

Optional accessories
* One-way /two-way nurse call
* Environmental controls
* Patient handset
* Foot pedal for adjustment of bed height
* Power drive
* Hinged power drive handles
* DIN accessory rails

Considerations

The tilt facility, when fitted, should only be used with the guidance of a clinical professional.

In certain circumstances there is an element of risk involved in the use of a device that attaches to the side of a bed such that there is the possibility of entrapment between the device and the mattress. This includes but is not limited to a bed pole (stick), bed rail or bed rail protector. The device may increase the risk of injury or even death to the bed occupant. Entrapment of limbs or body parts may occur with parts of the bed and the device. Some bed occupants may try to climb over a bed rail to get out of bed.

A risk assessment should be undertaken in each circumstance of use. The device should not be used in circumstances where there is a gap between the vertical components and the mattress. Users most at risk include those with physical or cognitive challenges or where the intended user's alertness is affected by medication.

Regular monitoring is recommended, particularly where the user's condition is changing.

Place Of Manufacture

Huntleigh Healthcare Ltd (United Kingdom)

Price Guide

POA

Models And Options

Models

Only one model available

Options

* One-way/two-way nurse call
* Power drive
* DIN accessory rails
* Environmental controls
* Patient handset
* Hinged power drive handles
* Foot pedals for adjustment of bed height

Dimensions

Specification Standard
Base Height (clearance) Unknown
Height 800 mm
Length From 2140 mm to 2400 mm
Load Capacity (supplier stated) 454 kg
Width 1180 mm

Additional Dimensions

Product Weight (approx)
with Power Drive............360kg
Head down tilt.................12 degrees
Foot down tilt...................12 degrees
Mattress length extended ..........2240mm
Mattress length short............2020mm
Mattress width short.............864mm

Setup And Maintenance

Maintenance

Cleaning Requirements
* Before cleaning, disconnect the bed from the mains power supply
* All the surfaces can be cleaned by moistening a soft cloth with hot water and a mild detergent
* Avoid splashing the actuators and handset
* Rinse with a cloth moistened with clean water and dry
* Phenol based cleaning agents should not be used

Requirements

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Suppliers

Arjo Australia Pty Ltd (prev ArjoHuntleigh) (H/O WA)
78 Forsyth St
O'connor
WA 6163
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: Adrian Male (gen mgr)
Toll Free: 1800 072 040 (National Customer Care)
Email: AHACustomerService@arjo.com
Website: http://www.arjo.com/en-au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (NSW)
Level 2, 4 Talavera Rd
Macquarie Park
NSW 2113
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Contact Person: David
Toll Free: 1800 072 040
Email: enquiries.au@arjo.com
Website: https://www.arjo.com/en-au/
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (QLD)
Unit 1
205 Queensport Road North
Murarrie
QLD 4172
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 07 3390 6544
Toll Free: 1800 072 040
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (SA)
489 South Rd
Regency Park
SA 5010
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 08 8363 1833
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au
Arjo Australia Pty Ltd (prev ArjoHuntleigh) (VIC)
10 / 1866 Princess Hwy
Clayton
VIC 3168
Australia
Sales: 1800 072 040 (National Customer Care)
Fax: 1800 009 077
Toll Free: 1800 072 040 (National Customer Care)
Email: enquiriesau@arjohuntleigh.com
Website: http://www.arjohuntleigh.com.au

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.