Product Detail

at magic logosubscribers   Login 
Send an email to make an enquiryEnquiry
PrintPrint
Qubicell Auto

Qubicell Auto Mattress Replacement System

QubiCell Auto is a pressure care mattress with an automatic air pressure adjusting system. By pressing one button, the system can automatically adjust to the most optimal pressure for the patient. It features special anti-sink rectangular cells on torso section and cell-on-cell structure. Antimicrobial stretch cover and filters offer additional protection. Suitable for treatments of all grades of pressure injuries or patients who are highly vulnerable to infection. Available as replacement system and as overlay.

Learn More 
Features: Alternating Air, Inflatable, Low Air Loss
  Qubicell Auto
Image Gallery: Qubicell Auto Qubicell Auto

Contact the supplier for pricing and availability

(1 supplier)

For information contact AT Aust on 1300 452 679

  • Additional info
  • Models and options
  • Dimensions
  • Setup and maintenance
  • Requirements

More Details

Max Firm Mode
* For nursing and rehabilitation
* Inflate to its firmest level with maximum stability. It will return to previous mode after 20 mins

Static Mode
* For patients sensitive to alternative mode
* Providing a stable surface with pressure lower than alternative mode. It will return to alternate mode after 20 mins

Seat Inflate + Static Mode
* For stable support in seating position
* Support with additional pressure to redistribute pressure centralized at sacral area and avoid excessive sinking while sitting

Seat Inflate + Alternate mode
* May be required for patient with muscle rigidity
* Support with additional pressure during alternate mode to relieve pressure centralized at sacral area

Alternate Mode
* Avoids long term pressurization
* Through periodically 1-in-2 alternating cycle with a cycle time of 10 minutes, the system can avoid long term pressurization on local tissue

Heel-Relief Cells
* Protecting vulnerable heels
* With Heel-Relief connector, heel can be suspended in air to completely eliminate pressure exerted to the heels

Special Rectangular Cells
* Optimal distribution and low shear force
* Cells conform to the contours of the body structure and movement to further absorb shear force caused by displacement (8? mattress only)

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

It is advisable that a health professional be consulted when considering a suitable pressure care product.

Place Of Manufacture

Unknown

More Details

Max Firm Mode
* For nursing and rehabilitation
* Inflate to its firmest level with maximum stability. It will return to previous mode after 20 mins

Static Mode
* For patients sensitive to alternative mode
* Providing a stable surface with pressure lower than alternative mode. It will return to alternate mode after 20 mins

Seat Inflate + Static Mode
* For stable support in seating position
* Support with additional pressure to redistribute pressure centralized at sacral area and avoid excessive sinking while sitting

Seat Inflate + Alternate mode
* May be required for patient with muscle rigidity
* Support with additional pressure during alternate mode to relieve pressure centralized at sacral area

Alternate Mode
* Avoids long term pressurization
* Through periodically 1-in-2 alternating cycle with a cycle time of 10 minutes, the system can avoid long term pressurization on local tissue

Heel-Relief Cells
* Protecting vulnerable heels
* With Heel-Relief connector, heel can be suspended in air to completely eliminate pressure exerted to the heels

Special Rectangular Cells
* Optimal distribution and low shear force
* Cells conform to the contours of the body structure and movement to further absorb shear force caused by displacement (8? mattress only)

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

It is advisable that a health professional be consulted when considering a suitable pressure care product.

Place Of Manufacture

Unknown

Models

Also available as overlay

Specification Overlay Replacement
Height 127 mm 203 mm
Length 2000 mm 2000 mm
Load Capacity (supplier stated) 180 kg 200 kg
Weight (kg) 5.6 kg 7.1 kg
Width 900 mm 900 mm

Additional Dimensions

* Overlay
Cell height......................431mm x 127mm
Cover Material...............Silver+ 2 ? directional Stretch
Cell Material...................Nylon / TPU

* Replacement
Cell height.......................508mm x 203mm
Cover Material...............Silver+ 2 - directional Stretch
Cell Material...................Nylon / TPU

* Pump
Lenght...............................291mm
Width.................................200mm
Depht................................117mm
Weight.............................. 2.2 Kg
Case Material...................Flame retardant ABS
Supply Voltage.................AC 220 ? 240V , 50Hz ; AC 120V / 60Hz
Operating Cycle...............10 mins

Maintenance

Check with supplier

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.

Suppliers

Supplier Location Contact Website
Statina Pty Ltd (part of JD Healthcare Group) Hornsby, NSW, Australia Sales: 1300 791 404
Fax: 1300 308 259
  Visit Website 

Similar Products

  • 21142000
    Alternating Air Overlay Mattress For Single Bed
  • 21142015
    Oska Alto Series 3 - V4
  • 21142013
    Carilex MedexCare Alternating Air Mattress
Loading...
Ref 21:14:2021
ISO 04.33.06
  • Contact
  • Donate
  • Virtual Tour
  • Disclaimer
  • Terms
  • Privacy
  • Home
  • Login/Sign-Up
  • Site Help
  • Feedback
  • Copyright & Disclaimer
  • Terms of Use
  • Privacy Policy
  • Who We Are
  • News & Events
  • Our History
  • Meet Our Team
  • Become a Member
  • Donate
  • Useful Links
  • What We Do
  • Client Services
  • Access
  • Training
  • @magic
  • AT Collaboration
  • Research
  • Assistive Technology
  • Browse Products
  • Product Search
  • 2nd-Hand Register
  • Suppliers Directory
  • @magic
  • Access
  • Access Consultancy
  • Access Training
  • Access Projects
  • Training
  • Publications
  • Strategic Plan
  • Annual Reports
  • Journal Extracts
  • @ a Glance Guides
  • Contact Us

Address

Assistive Technology Australia
(Independent Living Centre NSW)
Shop 4019 Westpoint Blacktown
17 Patrick Street
Blacktown
NSW 2148
Australia

Find Us

Shop 4019
Level 4 (Rooftop)
Westpoint Shopping Centre Blacktown
Enter car park via express ramp at the Alpha St roundabout (Map)

1300 452 679
02 9912 5800 (Reception)

02 8814 9656 (Fax)

Email: welcome@at-aust.org
Feedback:feedback@at-aust.org

Facebook: ILCNSW

ABN 44103 681 572

 

Copyright © 2009-2020 Independent Living Centre NSW trading as Assistive Technology Australia. Logo and name are trademarks of the Independent Living Centre NSW.