Optimum Air 9 Digital Alternating Support System

Optimum Air 9 System

Contact the suppliers for pricing and availability

(7 suppliers)

For information contact AT Aust on 1300 452 679

Short Description

A digitally controlled, electric air alternating mattress replacement system with a 1 in 3 alternation cycle time of twelve minutes. The system consists of a mattress and a pump. It comes with a vapour permeable, water resistant, and two way stretch top cover. It is suitable for users at high to very high risk of developing pressure areas. Available in one standard size.

Additional Info

More Details

Structure
* Cell in cell design which contributes to user safety by increasing the clearance between inflating
* Independent heel zone for vulnerable heel and lower leg area
* Static head cells to add to stability
* 19 cell in cell (including 3 static head cells and 5 narrow heel cells)
* Cell material 0.15mm TPU film laminated on 210 denier nylon fabric
* Base material Nylon fabric 420 denier with a 0.1mm TPU coating

Cover
* Material: PU coated polyester
* Vapour permeable, waterproof top cover with multi stretch fabric to help minimise friction and reduce shear
* Welded seams and full length waterfall skirt to aid in infection control

Attachment
* Hinged base to conform to bed movement
* Hose Connection: Press on dual connector hoses

Pump / Controls
* Electrically operated
* Adjustable digital control unit with eight comfort pressure settings
* Visible and audible alarm
* Timed transport and static functions for stable patient treatment
* Mode of Operation: Non-continuous

Safety Features
* CPR "D handle" release
* Internal side bolsters to assist with patient safety and lateral stability
* Automatic static cutout after 20 minutes

Accessories
* Included wheeled carry bag for transport, storage and documentation retention
* Optional control unit hooks with a range of shapes and sizes to suit a range of bed styles

Considerations

* All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

* It is advisable that a health professional be consulted when considering a suitable pressure care product.

Place Of Manufacture

Unknown

Price Guide

Price is Dear Jane Medical

Models And Options

Models

Only one model available

Options

* Control unit hooks

Dimensions

Specification Standard
Height 280 mm
Length 2000 mm
Load Capacity (supplier stated) 180 kg
Weight (kg) 11.6 kg
Width 880 mm

Additional Dimensions

Control System........................................................................ Digital micro controller
Cycle Time....................................................................................... 12 minutes (fixed)
Supply Voltage................................... 220-240V AC 50/60Hz; 0.2A for Control Unit
Fuse Rating........................................Mains Plug - 3AMP, Control Unit - 1AMP (x2)
Power Rating.........................................................................................................12VA
Standards........................................................................................................... CE, UL
Control unit height............................................................................................. 270mm
Control unit width............................................................................................... 315mm
Control unit depth.............................................................................................. 120mm
Control unit weight.................................................................................................3.5kg
Operating Environment Air humidity........................................................30% to 75%
Operating Environment Ambient temperature ...................0 degree to 40 degrees
Operating Altitude ...................................................................................Under 2000m

Setup And Maintenance

Maintenance

Infection Control and routine cleaning must be carried out in accordance with
your local Infection Control Policy. It is suggested that all disinfection be done with a high grade disinfectant in accordance with manufacturer's instructions.

Requirements

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Additional Images

Control Unit & Pump Optimum Air 9 Mattress Air Cells Air Pump Connector System In Pack

Suppliers

Confident Care Products (NSW)
65 Williamson Rd
Ingleburn
NSW 2565
Australia
Sales: 02 9605 5745
Fax: 02 9829 4244
Toll Free: 1800 020 025
Email: sales@confidentcare.com.au
Website: http://www.confidentcare.com.au
Confident Care Products (QLD)
Suite 6 / 281 Sandgate Rd
Albion
QLD 4010
Australia
Sales: 07 3262 7497
Fax: 07 3262 9244
Email: cbrugmans@confidentcare.com.au
Website: http://www.confidentcare.com.au
DearJane Medical
Suite 10/20 Barcoo Str
Roseville
NSW 2069
Australia
Sales: 02 8317 5097
Toll Free: 1300 770 161
Email: info@dearjane.com.au
Website: http://www.dearjane.com.au
Hospital at Home (Moorebank H/O)
Unit 1, 30 Heathcote Rd
Moorebank
NSW 2170
Australia
Sales: 1300 303 604
Contact Person: Lesley Carter
Email: sales@hospitalathome.com.au
Website: http://www.hospitalathome.com.au
Hospital at Home (Newcastle)
Unit 1, 69 Munibung Rd
Cardiff
NSW 2285
Australia
Sales: 1300 303 604
Contact Person: Ian and Gail Brewer
Email: sales@hospitalathome.com.au
Website: http://www.hospitalathome.com.au
Hospital at Home (Wagga Wagga)
352 Edward St
Wagga Wagga
NSW 2650
Australia
Sales: 02 6925 4966
Contact Person: Chantelle Montgomery
Email: sales@hospitalathome.com.au
Website: http://www.hospital-at-home.com.au
Statewide Home Health Care
501 Nepean Hwy
Brighton East
VIC 3187
Australia
Sales: 03 9591 6234
Fax: 03 9591 6292
Email: tim@shhc.com.au
Website: http://www.shhc.com.au

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.