Skip to Content
Login/Sign-Up Donate Contact Us
 
  Search

Assistive Technology Australia

Endless Possibilities for All

  • Home
  • Who We Are
  • What We Do
  • Product Search
  • Assistive Technology
  • Access
  • Training
  • Publications
  • Home
  • Who We Are
  • What We Do
  • Product Search
  • Assistive Technology
  • Access
  • Training
  • Publications

Product Detail

at magic logosubscribers   Login 
Send an email to make an enquiryEnquiry
PrintPrint
Theraflow

Theraflow Acute Alternating Mattress Replacement System

An electrically operated alternating air pressure mattress replacement system. It consists of a multi cell mattress and air control pump. Paired cells alternatively inflate and deflate. The system uses the energy within the mattress itself to alternately "pull" cells away from the user. This results in more pressure removal for longer periods of time and can be customised for use under the most vulnerable body parts. The cells alternate over a 14 minute cycle.

Learn More 
Features: Alternating Air, Inflatable, Vapour Permeable, Water Resistant

Options

* A.M.I. Multimedia WiFi Alert Module

  Theraflow
Image Gallery: Theraflow Theraflow

Contact the suppliers for pricing and availability

(26 suppliers)

For information contact AT Aust on 1300 452 679

  • Additional info
  • Models and options
  • Dimensions
  • Setup and maintenance
  • Requirements

More Details

DynamULink Turbocharged Deflation
* A patented cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets.
* This alternately removes almost all interface pressure under nearly 80% of the user's body
* The at risk heel area is completely elevated for nearly 30% of the alternation cycle.
* This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under user weight.

Structure
* 28 paired cells
* Four static head cells
* Cell material is TPU (thermoplastic polyurethane), high density, multi-zoned
* Two positioning handles on each side
* Cell cycle is paired one in two, 14 minutes per cycle

Cover
* Welded stretch, breathable Dartex which is water resistant

Pump / Controls
* Mode of operation in non continuous
* Transport function (hose end cap)
* Auto Startup
* Comfort Override Control
* Self Diagnostics
* Audible/visual alarm
* Mute Function
* Static Mode
* Care Mode
* Incline Mode
* Auto Anti Tamper

Safety Features
Infection Control: All outer surfaces are fully welded. A unique 'mattress within a mattress' design ensures complete protection.

Customised Features
* The system can be customised to focus therapy on particular areas of skin breakdown
* Elastic members can be quickly engaged and disengaged under the user - focusing therapy under at risk areas by up to 50% from standard mode.

Option details
* Optional A.M.I. Multimedia WiFi Alert Module: Tamper, water and shock proof multi-media system for all aspects of system use and patient care.

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

It is advisable that a health professional be consulted when considering a suitable pressure care product.

Place Of Manufacture

Australia

Price Guide

Price on application from Aidacare

More Details

DynamULink Turbocharged Deflation
* A patented cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets.
* This alternately removes almost all interface pressure under nearly 80% of the user's body
* The at risk heel area is completely elevated for nearly 30% of the alternation cycle.
* This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under user weight.

Structure
* 28 paired cells
* Four static head cells
* Cell material is TPU (thermoplastic polyurethane), high density, multi-zoned
* Two positioning handles on each side
* Cell cycle is paired one in two, 14 minutes per cycle

Cover
* Welded stretch, breathable Dartex which is water resistant

Pump / Controls
* Mode of operation in non continuous
* Transport function (hose end cap)
* Auto Startup
* Comfort Override Control
* Self Diagnostics
* Audible/visual alarm
* Mute Function
* Static Mode
* Care Mode
* Incline Mode
* Auto Anti Tamper

Safety Features
Infection Control: All outer surfaces are fully welded. A unique 'mattress within a mattress' design ensures complete protection.

Customised Features
* The system can be customised to focus therapy on particular areas of skin breakdown
* Elastic members can be quickly engaged and disengaged under the user - focusing therapy under at risk areas by up to 50% from standard mode.

Option details
* Optional A.M.I. Multimedia WiFi Alert Module: Tamper, water and shock proof multi-media system for all aspects of system use and patient care.

Considerations

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

It is advisable that a health professional be consulted when considering a suitable pressure care product.

Place Of Manufacture

Australia

Price Guide

Price on application from Aidacare

Models

Only one model available

Options

* A.M.I. Multimedia WiFi Alert Module

Specification Bariatric King Single Single
Height 250 mm 250 mm 250 mm
Length 2000 mm 2000 mm 2000 mm
Load Capacity (supplier stated) 350 kg 200 kg 200 kg
Weight (kg) Unknown Unknown Unknown
Width 1070 mm 1070 mm 900 mm

Additional Dimensions

Control Unit
Width 250 mm
Depth 170 mm
Height 250 mm

Maintenance

Follow the manufacturer's instructions for cleaning and maintenance

Standards

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For more information about standards also see
http://at-aust.org/home/assistive_technology/standards.html

TGA
Many of the items on the Assistive Technology Australia website are categorised as a Medical Device. Medical devices that are approved for use in Australia have been entered into a national database called the Australian Register of Therapeutic Goods (ARTG), which is maintained by the Therapeutic Goods Administration (TGA). You can ask the supplier for the ARTG number for the device you wish to purchase and search the ARTG for the entry. To access information on the ARTG visit www.tga.gov.au

When buying a medical device it is advisable to only choose a medical device that is recommended by a healthcare professional and has been included on the ARTG.

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre New South Wales (ILCNSW), operating as Assistive Technology Australia, is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILCNSW (Assistive Technology Australia) for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.

Suppliers

Supplier Location Contact Website
Aidacare (NSW - Albury) Lavington, NSW, Australia Sales: 02 6040 3444
Fax: 02 6040 3222
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Ballina) Ballina, NSW, Australia Sales: 02 6686 6644
Fax: 02 6686 9383
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Coffs Harbour) Coffs Harbour, NSW, Australia Sales: 02 6651 5333
Fax: 02 6652 1272
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Orange) Orange, NSW, Australia Sales: 0437 134 295
  Visit Website 
Aidacare (NSW - Port Macquarie) Port Macquarie, NSW, Australia Sales: 02 6581 0018
Fax: 02 6581 0038
  Visit Website 
Aidacare (NSW - Sydney North, Seven Hills) Seven Hills, NSW, Australia Sales: 02 8706 2330
Fax: 02 9624 4256
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Sydney South, Moorebank) - HO Moorebank, NSW, Australia Sales: 02 8706 2300
Fax: 02 9618 5111
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Sydney West, Blacktown) Blacktown, NSW, Australia Sales: 02 9621 4077
Toll Free: 1300 216 898
  Visit Website 
Aidacare (NSW - Tamworth) Tamworth, NSW, Australia Sales: 02 6761 2018
Fax: 02 6761 2090
  Visit Website 
Aidacare (NSW - Wollongong) Wollongong, NSW, Australia Sales: 02 4273 0184
Fax: 02 9618 5111
Toll Free: 1300 133 120
  Visit Website 
Aidacare (QLD - Brisbane North, Geebung) Geebung, QLD, Australia Sales: 07 3086 2950
Fax: 07 3865 7896
Toll Free: 1300 133 120
  Visit Website 
Aidacare (QLD - Brisbane South, Coopers Plains) Coopers Plains, QLD, Australia Sales: 07 3086 2900
Fax: 07 3345 7961
Toll Free: 1300216898
  Visit Website 
Aidacare (QLD - Gold Coast) Southport, QLD, Australia Sales: 07 5532 6070
Fax: 07 5503 1803
Toll Free: 1300 133 120
  Visit Website 
Aidacare (QLD - Hervey Bay) Pialba, QLD, Australia Sales: 07 4194 5019
Toll Free: 1300 133 120
  Visit Website 
Aidacare (QLD - Toowoomba) Toowoomba, QLD, Australia Sales: 07 3086 2990
Fax: 07 4632 6473
Toll Free: 1300 133 120
  Visit Website 
Aidacare (SA - Adelaide) Regency Park, SA, Australia Sales: 08 8118 5600
Fax: 08 8346 3236
Toll Free: 1300 133 120
  Visit Website 
Aidacare (TAS - Hobart) Cambridge, TAS, Australia Sales: 03 6229 4733
Fax: 03 6229 3676
Toll Free: 1300 133 120
  Visit Website 
Aidacare (TAS - Launceston) Kings Meadows, TAS, Australia Sales: 03 6344 8922
Fax: 03 6229 3676
Toll Free: 1300 133 120
  Visit Website 
Aidacare (VIC - Barwon) Geelong, VIC, Australia Sales: 03 5223 2263
Fax: 03 5223 2269
Toll Free: 1300 133 120
  Visit Website 
Aidacare (VIC - Bendigo) Bendigo, VIC, Australia Sales: 03 5441 8213
Fax: 03 5441 7762
Toll Free: 1300 133 120
  Visit Website 
Aidacare (VIC - Melbourne DC Office) Thomastown, VIC, Australia Sales: 03 9981 2100
Fax: 03 9384 2088
  Visit Website 
Aidacare (VIC - Melbourne North) Brunswick East, VIC, Australia Sales: 03 9981 2100 (H/O)
Fax: 03 9384 2088 (H/O)
Toll Free: 1300 133 120
  Visit Website 
Aidacare (VIC - Melbourne South) Cheltenham, VIC, Australia Sales: 03 9584 1644
Fax: 03 9584 0562
Toll Free: 1300 133 120
  Visit Website 
Aidacare (VIC - Mildura) Mildura, VIC, Australia Sales: 03 5022 0755
Fax: 03 5021 1845
Toll Free: 1300 133 120
  Visit Website 
Evocare Enoggera, QLD, Australia Sales: 07 3355 8000
Fax: 07 3355 5043
  Visit Website 
Patient Support Systems Pty Ltd Belrose, NSW, Australia Sales: 1800 432 247
Fax: 02 9844 5445
Toll Free: 1800 432 247
  Visit Website 

Similar Products

  • 21142015
    Oska Alto Series 3 - V4
  • 21142003
    Aspire Range of Active Air Alternating Overlays
  • 21142019
    Optimum Air 8 Digital Alternating Support System
  • 21142018
    Optimum Air 9 Digital Alternating Support System
Loading...
Ref 21:14:2008
ISO 04.33.06
  • Contact
  • Donate
  • Virtual Tour
  • Disclaimer
  • Terms
  • Privacy
  • Home
  • Login/Sign-Up
  • Site Help
  • Feedback
  • Copyright & Disclaimer
  • Terms of Use
  • Privacy Policy
  • Who We Are
  • News & Events
  • Our History
  • Meet Our Team
  • Become a Member
  • Donate
  • Useful Links
  • What We Do
  • Client Services
  • Access
  • Training
  • @magic
  • AT Collaboration
  • Research
  • Assistive Technology
  • Browse Products
  • Product Search
  • 2nd-Hand Register
  • Suppliers Directory
  • @magic
  • Access
  • Access Consultancy
  • Access Training
  • Access Projects
  • Training
  • Publications
  • Strategic Plan
  • Annual Reports
  • Journal Extracts
  • @ a Glance Guides
  • Contact Us

Address

Assistive Technology Australia
(Independent Living Centre NSW)
Shop 4019 Westpoint Blacktown
17 Patrick Street
Blacktown
NSW 2148
Australia

Find Us

Shop 4019
Level 4 (Rooftop)
Westpoint Shopping Centre Blacktown
Enter car park via express ramp at the Alpha St roundabout (Map)

1300 452 679
02 9912 5800 (Reception)

02 8814 9656 (Fax)

Email: welcome@at-aust.org
Feedback:feedback@at-aust.org

Facebook: ILCNSW

ABN 44103 681 572

 

Copyright © 2009-2020 Independent Living Centre NSW trading as Assistive Technology Australia. Logo and name are trademarks of the Independent Living Centre NSW.